Tripp Lite series 3.7kW 208/230V Single-Phase Local Metered PDU – 16 C13 & 4 C19 Outlets, C20/L6-20P Input, 10-ft. (3.05 m) Cord, 40 in. 0U Rack

$348.38

Brand: Tripp Lite
Part Number (MPN): PDUMV20HV-36
UPC / GTIN: 037332255921
Datasheet: PDF

Tripp Lite series 3.7kW 208/230V Single-Phase Local Metered PDU – 16 C13 & 4 C19 Outlets, C20/L6-20P Input, 10-ft. (3.05 m) Cord, 40 in. 0U Rack

Toronto Stock: 10 available
Manufacturer Warehouse: 129 available
*Items typically ship within 3-4 weeks if stock at factory
Need project pricing? Add items to your cart to request a custom project quote.

Quick Specs

  • 16 C13 and 4 C19 208/230V outlets compatible with Eaton Tripp Lite power cords
  • Digital ammeter for on-site real-time load monitoring helps prevent power overloads
  • Switchless design helps prevent accidental shutdowns that can lead to costly downtime
  • 10 ft. (3.1 m) detachable cord with L6-20P single-phase input connects to AC power source
  • 40 in. 0U PDU with included mounting brackets installs in rack or under counter

Features

Single-Phase PDU Distributes and Monitors Network-Grade Power in Real Time
This local metered rack PDU (rPDU) provides real-time local reporting of the total load level via its built-in digital current metering. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMV20HV-36 features 16 C13 and four C19 208/230V outlets for connecting equipment. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged. The switchless design helps prevent an accidental shutdown, which could lead to costly downtime.

Digital Load Meter Helps Prevent Potentially Expensive Overloads
A digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low.

Versatile Installation Options Give You Plenty of Choices
The 40-inch 0U PDU mounts vertically in an EIA-standard 19-inch rack using the included toolless mounting buttons or the included mounting brackets with user-supplied hardware. You may also use the brackets to secure the PDU to the underside of a counter with the addition of two user-supplied screws. Bolt-down retention brackets keep power cords organized and your rack free of clutter.

Compatible with a Variety of Input Cords to Fit Your Facility’s Power Source
The PDU’s C20 inlet accepts a variety of 16A international cordsets. An included 10-ft. (3.05 m) cord with NEMA L6-20P input plug connects to an AC power source, generator or protected UPS system to distribute power to connected loads.

Package Includes

  • PDUMV20HV-36 3.7kW Single-Phase Local Metered PDU
  • (20) Plug-lock insert sleeves
  • C19 to L6-20P input cord, 10-ft. (3.05 m)
  • Rack-mounting hardware
  • Owner’s manual
Weight 9.5 lbs
Dimensions 41.5 × 3.5 × 5 in
UPC Code

037332255921

Cord Length

10.01

Max Input Amps

16

Brand

PDU Type

Local Metered

Input Phase

Single-Phase

PDU Input Voltage

208; 230

Maximum Input Amps Details

Agency de-rated to 16A continuous

Input Connection Type

L6-20P detachable cordset, C20 inlet available

PDU Plug Type

NEMA L6-20P; IEC-320 C20

Input Cord Length (m)

3.05

Output Capacity Details

3.68kW (230V), 3.33kW (208V) / 16A total capacity; 16A max per C19 outlet; 12A (10A CE) max per C13 outlet

Frequency Compatibility

50 / 60 Hz

Output Receptacle Details

Compatible with Eaton Tripp Lite Power Cords

Output Receptacles

(16) C13; (4) C19

Output Nominal Voltage

208/230V

Front Panel LCD Display

Digital meter reports PDU output current in amps

Material of Construction

Aluminum

Rack Height

0U

Form Factors Supported

0u vertical installation in equipment racks, plus under-counter and wallmount

PDU Form Factor

Vertical (0U)

Shipping Weight (kg)

4.31

Unit Dimensions (hwd / cm)

101 x 5.7 x 9.5

Unit Weight (kg)

2.36

Operating Temperature Range

32° to 104°F (0° to 40°C)

Storage Temperature Range

-22° to 122°F (-30° to 50°C)

Relative Humidity

0-95% non-condensing

Operating Elevation

0-10000 ft. (0-3000 m)

Product Certifications

IEC 62368-1; RETIE (Colombia); GOST (Russia); NOM (Mexico)

Product Compliance

RoHS; EAC (Belarus, Kazakhstan, Russia); UKCA

Product Warranty Period (Worldwide)

2-year limited warranty

Part Number

Description

WEXT1C

Extended Warranty and Technical Support for Select Products – DC Power, KVM, PDU, Inverters, Power Management

WEXT2C

Extended Warranty and Technical Support for Select Products – DC Power Supplies, KVM Switches, PDUs, Power Inverters, Power Management

WEXT3C

Extended Warranty and Technical Support for Select Products – Cables and Connectivity, DC Power Supplies, KVM Switches, PDUs, Power Inverters

Reviews

There are no reviews yet.

Be the first to review “Tripp Lite series 3.7kW 208/230V Single-Phase Local Metered PDU – 16 C13 & 4 C19 Outlets, C20/L6-20P Input, 10-ft. (3.05 m) Cord, 40 in. 0U Rack”

Your email address will not be published. Required fields are marked *