Tripp Lite series 5.8kW Single-Phase Local Metered PDU, 200-240V Outlets (8 C19 and 40 C13), L6-30P, 10 ft. (3.05 m) Cord, 0U Vertical, TAA, 70 in.

$703.55

Brand: Tripp Lite
Part Number (MPN): PDUMV30HV2
UPC / GTIN: 037332182807
Datasheet: PDF

Tripp Lite series 5.8kW Single-Phase Local Metered PDU, 200-240V Outlets (8 C19 and 40 C13), L6-30P, 10 ft. (3.05 m) Cord, 0U Vertical, TAA, 70 in.

Toronto Stock: 8 available
Need project pricing? Add items to your cart to request a custom project quote.

Quick Specs

  • Ideal for server rooms, network closets and data centers
  • Dual load banks with 24 outlets each (4 C19 and 20 C13)
  • Compatible with Eaton Tripp Lite power cords to simplify deployment and enhance reliability
  • Dedicated 20A circuit breakers protect output
  • NEMA L6-30P input plug with 10 ft. (3 m) cord
  • Ready for immediate toolless 0U installation

Overview

The 70-inch (178-centimeter) PDUMV30HV2 30A 200-240V 5.8kW Single-Phase Local Metered Power Distribution Unit features 48 outlets for distributing single-phase AC power to rack-mounted equipment, including computers, routers, switches and servers.

Outlets are arranged in two separate load banks, each with 24 outlets (4 C19 and 20 C13), a dedicated 20A circuit breaker and a digital meter that reports the bank’s real-time output current in amps. The ammeters let you visually monitor each bank and maintain balanced loads to prevent circuit overloads and downtime due to breakers tripping. Special guards prevent the breakers from tripping accidentally. Outlets, breakers and ammeters are color-coded and labeled for easy identification.

An ideal PDU for server rooms, network closets and data centers, the PDUMV30HV2’s all-metal housing comes ready to mount vertically in your rack using the preinstalled 9 mm buttons or the included hardware. The NEMA L6-30P input plug with 10-ft. (3.05 m) cord connects to your facility’s compatible AC power source, generator or protected UPS. Included C20 and C14 plug-lock inserts connect to your components’ plugs to ensure they remain connected and continuously powered. Use the included ground screw to connect any equipment that requires a chassis ground.

Features

Digital Meters Help Prevent Overloads

  • Dual digital ammeters report real-time output current in amps
  • Visual monitoring of PDU load level prevents overloading as more equipment is connected

Distributes Plenty of Single-Phase Power

  • 30A 200-240V 5.8kW local metered rack PDU (rPDU) (agency derated to 24A continuous)
  • Dual load banks with separate 20A circuit breakers and digital ammeters
  • 48 outlets—24 per bank (4 C19 and 20 C13)—distribute single-phase power to connected equipment
  • Special guards prevent breakers from accidentally tripping
  • Each bank is color-coded and labeled for convenient identification

Connects to AC Power Source

  • NEMA L6-30P input plug with 10-ft. (3.05 m) cord for easy connection to main power source, generator or protected UPS
  • Included plug-lock inserts ensure components remain connected and powered
  • Included ground screw for equipment requiring chassis ground

Easy to Mount With or Without Tools

  • Ready for immediate toolless 0U installation using preinstalled 9 mm mounting buttons (spare 2.9 mm and 4.6 mm buttons included)
  • Nut-and-bolt vertical installation possible with included mounting hardware
  • Use included PDUMVROTATEBRKT mounting accessory for installation with outlets facing rear

TAA-Compliant

  • Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases

Package Includes

  • PDUMV30HV2 30A 200-240V 5.8kW Single-Phase Local Metered PDU
  • Plug-lock inserts (8 C20, 40 C13)
  • Spare installation buttons, 2.9 mm/4.6 mm
  • Ground screw
  • Mounting hardware
  • Owner’s Manual
Weight 16.98 lbs
Dimensions 75.87 × 9.65 × 6.89 in
UPC Code

037332182807

Cord Length

10.01

Max Input Amps

24

Brand

PDU Type

Local Metered

Input Phase

Single-Phase

PDU Input Voltage

200; 208; 220; 230; 240

Maximum Input Amps Details

Agency de-rated to 24A continuous

PDU Plug Type

NEMA L6-30P

Input Cord Length (m)

3.05

Output Capacity Details

5.8kW (240V), 5.5kW (230V), 5.3kW (220V), 5kW (208V), 4.8kW (200V) total capacity / 30A max (Agency de-rated to 24A), 20A max per breakered outlet bank; 16A max per C19 outlet; 12A max per C13 outlet

Frequency Compatibility

50 / 60 Hz

Output Receptacle Details

Compatible with Eaton Tripp Lite Power Cords

Output Receptacles

(40) C13; (8) C19

Output Nominal Voltage

200-240V

Overload Protection

Two 20A breakers protect 24 outlets each

Reported Load Segments

Supports local monitoring of output current for each output load bank; Outlets, circuit breakers and current meters are color-coded and labeled for easy identification (Black: 20A Bank 1 / Gray: 20A Bank 2)

Front Panel LCD Display

Set of two digital current meters report output current in two segments

Material of Construction

Metal

Rack Height

0U

Form Factors Supported

0u vertical installation in equipment racks, plus under-counter and wallmount

PDU Form Factor

Vertical (0U)

Shipping Dimensions (hwd / cm)

17.50 x 24.51 x 192.71

Shipping Weight (kg)

7.70

Unit Dimensions (hwd / cm)

177.8 x 6.88 x 6.4

Unit Weight (kg)

5.60

Operating Temperature Range

32° to 122°F (0° to 50°C)

Storage Temperature Range

-22° to 140°F (-30° to 60°C)

Relative Humidity

5% to 95% non-condensing

Operating Elevation

0-10000 ft. (0-3000 m)

Product Certifications

RETIE (Colombia); NOM (Mexico); UL 62368-1

Product Compliance

RoHS; FCC Part 15 Class B (USA); Trade Agreements Act (TAA)

Product Warranty Period (Worldwide)

2-year limited warranty

WEXT1D

Extended Warranty and Technical Support for Select Products – Isolation Transformers, KVM, PDU, Inverters

WEXT2D

Extended Warranty and Technical Support for Select Products – Isolation Transformers, KVM Switches, PDUs, Power Inverters

WEXT3D

Extended Warranty and Technical Support for Select Products – Isolation Transformers, KVM Switches, PDUs, Power Inverters

Reviews

There are no reviews yet.

Be the first to review “Tripp Lite series 5.8kW Single-Phase Local Metered PDU, 200-240V Outlets (8 C19 and 40 C13), L6-30P, 10 ft. (3.05 m) Cord, 0U Vertical, TAA, 70 in.”

Your email address will not be published. Required fields are marked *