Quick Specs

  • Offers network-grade protection against power failures and voltage fluctuations
  • Zero transfer time between on-line and battery modes for uninterrupted operation
  • Optional external battery packs provide additional runtime for applications requiring it
  • Optional WEBCARDLXE network interface required to use Auto Probe feature
  • ENERGY STAR-certified to save electricity, lower costs, and protect the environment

Features

Double-Conversion UPS Protects Equipment against Damage, Downtime and Data Loss This 200/208/220/230/240V 50/60 Hz UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with +/-2% voltage regulation in online and battery modes. Featuring a 2700W capacity, high 0.9 power factor, 570 joules of surge suppression, true on-line operation with pure sine wave output and zero transfer time in on-line double-conversion mode, the SmartOnline® SU3000LCD2UHV double-conversion UPS provides the highest level of AC power protection and battery backup for critical network closet, computer room and data center equipment.

 

Set Power Strategies to Reflect Your Protection Priorities Pick your power strategy, from precise power for sensitive systems to the highest possible electrical efficiency, while ensuring 100% uptime. Choose from five selectable strategies: Max Efficiency, Max Quality, Frequency Regulation, Frequency Conversion and Auto Adaptive, which automatically offers increased efficiency when power conditions are good and enhanced power quality when power conditions are poor.

 

Individually Controllable Load Banks Let You Access and Control Outlets Remotely Four NEMA 6-15/20R outlets are split evenly into two switchable load banks, allowing you to reboot select components or shed loads remotely. In addition to those four outlets, this UPS provides two more NEMA 6-15/20R outlets in their own unswitched bank, as well as two NEMA L6-20R outlet dongles, for powering critical components.

 

Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages The field-replaceable, hot-swappable internal battery provides 13.5 minutes of support at half load (1350W) and five minutes at full load (2700W), keeping protected equipment operational through power failures. For mission-critical applications demanding scalable extended runtime, the UPS supports “smart” external battery packs, such as BP72V18-2US (sold separately). Both the internal and external batteries are automatically sensed and configured during replacement to offer accurate runtime-remaining and battery age notifications during outages. The intelligent battery management system with temperature-compensated charging extends battery life.

 

Automatic Bypass Maintains Utility Output During Fault Conditions Auto-bypass mode keeps connected equipment powered and operational, even during UPS fault conditions.

 

ENERGY STAR-Certified to Help You Save Money and Protect the Environment By meeting strict EPA efficiency guidelines, this ENERGY STAR-certified UPS system helps you save money and energy. A power-saving Economy mode setting option offers enhanced efficiency and reduced BTU output when utility power is already high quality.

 

Automatically Turns Back On After Power Is Restored Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement.

 

Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring The front-panel LCD screen reports UPS operating mode, detailed UPS status and site-power information, as well as a variety of advanced UPS setup and configuration options. LEDs indicate AC input/output, battery and fault status.

 

Advanced Communications Ports Allow for Automatic Saves and Shutdowns RS-232 and HID-compliant USB ports connect to a computer running free downloadable PowerAlert® software to enable safe unattended file saves and system shutdown in case of a prolonged power failure. An EPO port connects the UPS to a contact closure switch to enable emergency inverter shutdown. Cables are included.

 

Optional WEBCARDLXE Network Interface Offers 24/7 Access The SU3000LCD2UHV includes a slot for an optional Java-free HTML5-based WEBCARDLXE (sold separately) that enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Automated alerts help prevent accidental overloads, power loss and downtime. WEBCARDLXE 15.5.2 or later is required to use the Auto Probe feature, which can prevent costly service calls by automatically rebooting non-responsive network devices.

 

Versatile Installation Options Hardware is included for mounting the UPS system in 2U of space in an EIA-standard 19-inch 4-post rack. Use the optional 2POSTRMKITWM (sold separately) for 2-post rack mounting or the optional 2-9USTAND (sold separately) for mounting in an upright tower position. The 10-ft. (3.05 m) power cord with NEMA L6-20P plug connects to any compatible AC outlet.

Package Includes

  • SU3000LCD2UHV SmartOnline Double-Conversion UPS
  • USB cable
  • RS-232 cable
  • EPO cable
  • 4-post rack-mounting hardware
  • Owner’s manual
Weight 86 lbs
Dimensions 29.92 × 23.62 × 9.45 in
UPC Code

037332180742

Cord Length

10.17

Max Input Amps

15

Rack Depth

28

Output (W)

2700

Output VA

3000

Joule Rating

570

Brand

UPS Type

On-Line

Input Phase

Single-Phase

Rated input current (Maximum Load)

14.97A

Nominal Input Voltage(s) Supported

200V AC; 208V AC; 220V AC; 230V AC; 240V AC

UPS Input Connection Type

L6-20P

UPS Input Cord Length (ft.)

10

UPS Input Cord Length (m)

3.1

Output Capacity (kVA)

3

Output Capacity (kW)

2.7

Output Capacity Details

DE-RATING INFORMATION: Max output in Frequency Conversion mode is reduced to 1890 watts for 208/220/230/240V output voltages; Max output is reduced to 2160W at 200V output voltage in all operating modes OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 3 minutes, 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits).

Power Factor

0.9

Crest Factor

3:1

Nominal Voltage Details

Nominal output voltage is user configured on first power-on

Frequency Compatibility

50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion

Frequency Compatibility Details

Output frequency matches input nominal on startup; Output capacity de-rates by 30% during frequency conversion operation

Output Voltage Regulation (Line Mode)

+/- 2%

Output Voltage Regulation (Economy Line Mode)

+/- 10%

Output Voltage Regulation (Battery Mode)

+/- 2%

Load Management Receptacles

Two switchable outlet load banks (2 NEMA 6-15/20R outlets per bank)

Output AC Waveform (AC Mode)

Pure Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

Nominal Output Voltage(s) Supported

200V; 208V; 220V; 230V; 240V

Output Receptacles

(6) 6-15/20R; (2) L6-20R

Individually Controllable Load Banks

Yes

Battery Type

Valve Regulated Lead Acid (VRLA)

Runtime Full Load (min.)

5 min. (2700W)

Runtime Half Load (min.)

13.5 min. (1350W)

Expandable Runtime

Yes

External Battery Pack Compatibility

BP72V18-2US (multi-pack compatible)

DC System Voltage (VDC)

72

Battery Recharge Rate (Included Batteries)

3.0 hours from 10% to 90% (typical, full load discharge)

Battery Access

Front panel battery access door

Internal UPS Replacement Battery Cartridge

RBC72S

Battery Replacement Description

Hot-swappable, replaceable batteries

Voltage Regulation Description

Online, double-conversion power conditioning

Overvoltage Correction

2% output voltage regulation during overvoltages to 288

Undervoltage Correction

2% output voltage regulation during undervoltages to 160V (100% load), 130V (70% load), 100V (30% load)

Front Panel LCD Display

Interactive front-panel LCD interface reports UPS operating mode, detailed UPS status and site-power information; LCD interface also enables a variety of advanced UPS setup and configuration options

Switches

5 front panel switches: On/Off, Up, Down and Escape

Alarm Cancel Operation

Power-fail alarm can be silenced by following on-screen prompts

Audible Alarm

Audible alarm indicates power failure, low battery, overload and fault

LED Indicators

4 front panel LEDs: AC input (green), AC output (green), Battery (yellow), Fault (red)

UPS Dataline Suppression Details

Single line dialup / network dataline protection included

EMI / RFI AC Noise Suppression

Yes

AC Suppression Joule Rating

570

AC Suppression Response Time

Instantaneous

Primary Form Factor

Rackmount

Rack Height

2U

Cooling Method

Fan

Installation Form Factors Supported with Optional Accessories

2 post rackmount ( 2POSTRMKITWM ); Tower ( 2-9USTAND )

Minimum Required Rack Depth (cm)

71.12

Minimum Required Rack Depth with External Battery Pack (in.)

30.25

Minimum Required Rack Depth without External Battery Pack (in.)

29.25

Primary UPS Depth (mm)

616

Primary UPS Height (mm)

88

Primary UPS Width (mm)

438

Shipping Dimensions (hwd / cm)

24.00 x 59.99 x 76.00

Shipping Weight (kg)

39.01

UPS Housing Material

Metal

UPS Power Module Dimensions (hwd, cm)

8.79 x 43.79 x 61.60

UPS Power Module Weight (kg)

32.12

Unit Weight (kg)

32.12

Mounting Details

4 post installation accessories included

Operating Temperature Range

32° to 104°F (0° to 40°C)

Storage Temperature Range

5° to 122°F (-15° to 50°C)

Relative Humidity

5 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

933

AC Economy Mode BTU / Hr. (Full Load)

588

AC Mode Efficiency Rating (100% Load)

>90%

AC Economy Mode Efficiency Rating (100% Load)

>95%

Online Mode Heat Dissipation (BTU/Hr) @ Full Load

933

Battery Mode Heat Dissipation (BTU/Hr) @ Full Load

1399

Operating Elevation

0-10000 ft. (0-3000 m)

Audible Noise

<50dB at front side 1M

Network Management Cards

WEBCARDLXE

Network Monitoring Port Description

Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 plus assignable contact closure pin functions for On-battery, On bypass, Output-on and Low-battery conditions and remote Shutdown, Output-off, Reboot and Power-toggle operations

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert

Communications Cable

USB and DB9 cabling included

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

Network Management Card Description

Network management card optional

Communications Interface

Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)

Transfer Time

0 ms

Low Voltage Transfer to Battery Power (Setpoint)

160V (100% load), 140V (66% load), 120V (33% load)

High Voltage Transfer to Battery Power (Setpoint)

288V

Cold Start (Startup in Battery Mode During a Power Failure)

Cold-start operation supported

High Availability UPS Features

Automatic inverter bypass; Hot swappable batteries; Remote management; Surge/noise protection; Zero transfer time; Auto Probe Monitoring (requires WEBCARDLXE)

Green Energy-Saving Features

High efficiency economy mode operation; Individually controllable load banks

Grounding Details

Back panel grounding lug included

UPS Applications

Mission Critical Applications

Product Certifications

CSA (Canada); NOM (Mexico); UL 1778

Product Compliance

RoHS; CE (Europe); ENERGY STAR Qualified; FCC Part 15 Class A (USA)

Product Warranty Period (Worldwide)

2-year limited warranty

Connected Equipment Insurance (U.S., Canada & Puerto Rico)

$250,000 Ultimate Lifetime Insurance

TLWFLN72XX6009UC

2-Year Onsite Service Contract -2501-6000 VA UPS, Smart, SMX, SU systems

TLWFLN73XX6009UC

3-Year Onsite Service Contract -2501-6000 VA UPS, Smart, SMX, SU systems

TLWFLN75XX6009UC

5-Year Onsite Service Contract -2501-6000 VA UPS, Smart, SMX, SU systems

TL9SW3Y3000UC

3-Year Extended Warranty SU 2501-3000 VA UPS systems

TL9SW5Y3000UC

5-Year Extended Warranty SU 2501-3000 VA UPS systems

TLAS00NXXX6009UC

UPS Assembly on UPS Systems 0-6000 VA for select products, Smart, SMX, SU UPS

Part Number

Description

TLSU05NXXX6009UC

UPS Startup on UPS Systems 0-6000 VA for select products, Smart, SMX, SU UPS

Reviews

There are no reviews yet.

Be the first to review “Tripp Lite series 208/240V 3000VA 2.7kW Double-Conversion UPS – 8 Outlets, Extended Run, Card Slot, LCD, USB, DB9, 2U”

Your email address will not be published. Required fields are marked *

Compatible accessories