Tripp Lite series SmartOnline 208/120V UPS With Step-Down Transformer – On-Line Double-Conversion, 3000VA 2700W, 4U, Network Card Option

$4,890.91

Brand: Tripp Lite
Part Number (MPN): SU3000LCD2UHVTF
UPC / GTIN: 037332241719
Datasheet: PDF

Tripp Lite series SmartOnline 208/120V UPS With Step-Down Transformer – On-Line Double-Conversion, 3000VA 2700W, 4U, Network Card Option

Status: On Backorder (Contact us for lead times)
Need project pricing? Add items to your cart to request a custom project quote.

Quick Specs

  • Offers protected 208V and 120V network-grade output power for critical IT applications
  • Zero transfer time between on-line and battery modes for uninterrupted operation
  • UPS + step-down transformer offer power protection of both 208V and 120V network devices
  • Optional external battery packs provide additional runtime for extended-run applications
  • Optional WEBCARDLXE network interface required to use Auto Probe feature

Features

2U Double-Conversion UPS Protects Equipment against Damage, Downtime and Data Loss This 208V and 120V 60 Hz UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with +/-2% voltage regulation in both on-line and battery modes. Featuring a 2.7kW capacity, high 0.9 power factor, 570 joules of surge suppression, true on-line operation with pure sine wave output and zero transfer time in on-line double-conversion mode, the SmartOnline® SU3000LCD2UHVTF double-conversion UPS provides the highest level of AC power protection and battery backup for critical network closet, computer room and data center equipment. With the included 2U step-down transformer, this 3kVA UPS system can support both low- and high-voltage equipment. Set Power Strategies to Reflect Your Protection Priorities Pick your power strategy, from precise power for sensitive systems to the highest possible electrical efficiency, while ensuring 100% uptime. Choose from four selectable strategies: Max Efficiency, Max Quality, Frequency Regulation and Auto Adaptive, which automatically offers increased efficiency when utility power conditions are good and enhanced power quality when power conditions are poor. Individually Controllable Load Banks Let You Access and Control Outlets Remotely The UPS and transformer combined feature 20 outlets in total—12 unswitched NEMA 5-15/20R on the transformer, six NEMA 6-15/20R on the UPS and one unswitched NEMA L6-20R on each. Four NEMA 6-15/20R outlets are split into two switchable load banks, allowing you to reboot select components or shed loads remotely. Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages The field-replaceable, hot-swappable internal battery provides 13.5 minutes of support at half load (1350W) and five minutes at full load (2700W), keeping protected equipment operational through power failures. For mission-critical applications demanding scalable extended runtime, the UPS supports “smart” external battery packs, such as BP72V18-2US (sold separately). Both the internal batteries and sensor-enabled external battery packs are automatically sensed and configured during installation and replacement to offer accurate remaining runtime during outages and battery-age notifications. The intelligent battery management system with temperature-compensated charging extends battery life. Automatic Bypass Maintains Utility Output During Fault Conditions Auto-bypass mode keeps connected equipment powered and operational, even during UPS fault conditions. Automatically Turns Back On When Power Is Restored Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement. Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring The front-panel LCD screen reports UPS operating mode, detailed UPS status and site-power information, as well as a variety of advanced UPS setup and configuration options. LEDs indicate AC input/output, battery and fault status. Advanced Communications Ports Allow for Automatic Saves and Shutdowns RS-232 and HID-compliant USB ports connect to a computer running free downloadable PowerAlert® software to enable safe unattended file saves and system shutdown in case of a prolonged power failure. An EPO port connects the UPS to a contact closure switch to enable emergency inverter shutdown. Cables are included. Optional WEBCARDLXE Network Interface Offers 24/7 Access An accessory slot accommodates the optional Java-free HTML5-based WEBCARDLXE (sold separately) that enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Automated alerts help prevent accidental overloads, power loss and downtime. WEBCARDLXE 15.5.2 or later is required to use the Auto Probe feature, which can prevent costly service calls by automatically rebooting non-responsive network devices. Versatile Installation Options in Your Data Center or Network Closet Hardware is included for mounting the UPS system and transformer in 4U of space in an EIA-standard 19-inch 4-post rack. Use two optional 2POSTRMKITWM kits for 2-post rack mounting or the optional 2-9USTAND for mounting in an upright tower position (both accessories sold separately). The 10-ft. (3.05 m) input power cord with NEMA L6-20P plug connects to any compatible AC outlet.

Package Includes

  • SU3000LCD2UHVTF 2U SmartOnline Double-Conversion UPS
  • SU5000XFMRT2U20 2U 208V to 120V Step-Down Isolation Transformer
  • USB cable
  • DB9 cable
  • EPO cable
  • Rack-mounting hardware
  • Owner’s manual
Weight 192 lbs
Dimensions 25 × 40 × 30 in
UPC Code

037332241719

Cord Length

10.17

Max Input Amps

15

Rack Depth

28

Output (W)

2700

Output VA

3000

Joule Rating

570

Brand

UPS Type

On-Line

Input Phase

Single-Phase

Rated input current (Maximum Load)

14.97A

Nominal Input Voltage(s) Supported

208V AC

UPS Input Connection Type

L6-20P

UPS Input Cord Length (ft.)

10

UPS Input Cord Length (m)

3.1

Output Capacity (kVA)

3

Output Capacity (kW)

2.7

Output Capacity Details

OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 3 minutes, 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits).

Power Factor

0.9

Crest Factor

3:1

Nominal Voltage Details

IMPORTANT! Please ensure the UPS is configured for 208V output when used with the included step-down transformer module

Frequency Compatibility

60 Hz

Frequency Compatibility Details

IMPORTANT! Please ensure the UPS is configured for 60Hz output when used with the included step-down transformer module

Output Voltage Regulation (Line Mode)

+/- 2%

Output Voltage Regulation (Economy Line Mode)

+/- 10%

Output Voltage Regulation (Battery Mode)

+/- 2%

Load Management Receptacles

Two switchable outlet load banks (2 NEMA 6-15/20R outlets per bank)

Output Circuit Breakers

Included 2U transformer module includes four 20A 120V circuit breakers (each protects 3 NEMA 5-15/20R outlets).

Output AC Waveform (AC Mode)

Pure Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

Nominal Output Voltage(s) Supported

120V; 208V

Output Receptacles

(12) 5-15/20R; (6) 6-15/20R; (2) L6-20R

Individually Controllable Load Banks

Yes

Battery Type

Valve Regulated Lead Acid (VRLA)

Runtime Full Load (min.)

5 min. (2700W)

Runtime Half Load (min.)

13.5 min. (1350W)

Expandable Runtime

Yes

External Battery Pack Compatibility

BP72V18-2US (multi-pack compatible)

DC System Voltage (VDC)

72

Battery Recharge Rate (Included Batteries)

3.0 hours from 10% to 90% (typical, full load discharge)

Battery Access

Front panel battery access door

Internal UPS Replacement Battery Cartridge

RBC72S

Battery Replacement Description

Hot-swappable, replaceable batteries

Voltage Regulation Description

Online, double-conversion power conditioning

Overvoltage Correction

2% output voltage regulation during overvoltages to 288

Undervoltage Correction

2% output voltage regulation during undervoltages to 160V (100% load), 130V (70% load), 100V (30% load)

Front Panel LCD Display

Interactive front-panel LCD interface reports UPS operating mode, detailed UPS status and site-power information; LCD interface also enables a variety of advanced UPS setup and configuration options

Switches

5 front panel switches: On/Off, Up, Down and Escape

Alarm Cancel Operation

Power-fail alarm can be silenced by following on-screen prompts

Audible Alarm

Audible alarm indicates power failure, low battery, overload and fault

LED Indicators

4 front panel LEDs: AC input (green), AC output (green), Battery (yellow), Fault (red)

UPS Dataline Suppression Details

Single line dialup / network dataline protection included

EMI / RFI AC Noise Suppression

Yes

AC Suppression Joule Rating

570

AC Suppression Response Time

Instantaneous

Primary Form Factor

Rackmount

Rack Height

4U

Cooling Method

Fan

Installation Form Factors Supported with Optional Accessories

2 post rackmount ( 2POSTRMKITWM ); Tower ( 2-9USTAND )

Minimum Required Rack Depth (cm)

71.12

Minimum Required Rack Depth with External Battery Pack (in.)

30.25

Minimum Required Rack Depth without External Battery Pack (in.)

29.25

Optional Mounting Accessory Notes

Quantity two 2POSTRMKITWM accessories are required for 2 post rackmount installation; Quantity one 2-9USTAND accessory required for upright tower installation

Primary UPS Depth (mm)

616

Primary UPS Height (mm)

177

Primary UPS Width (mm)

440

Shipping Weight (kg)

87.09

UPS Housing Material

Metal

UPS Power Module Weight (kg)

60.70

Unit Weight (kg)

60.70

Mounting Details

4 post installation accessories included (2 sets)

Operating Temperature Range

32° to 104°F (0° to 40°C)

Storage Temperature Range

5° to 122°F (-15° to 50°C)

Relative Humidity

5 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

933

AC Economy Mode BTU / Hr. (Full Load)

588

AC Mode Efficiency Rating (100% Load)

>90%

AC Economy Mode Efficiency Rating (100% Load)

>95%

Online Mode Heat Dissipation (BTU/Hr) @ Full Load

933

Battery Mode Heat Dissipation (BTU/Hr) @ Full Load

1399

Audible Noise

<50dB at front side 1M

Network Management Cards

WEBCARDLXE

Network Monitoring Port Description

Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 plus assignable contact closure pin functions for On-battery, On bypass, Output-on and Low-battery conditions and remote Shutdown, Output-off, Reboot and Power-toggle operations

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert

Communications Cable

USB and DB9 cabling included

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

Network Management Card Description

Network management card optional

Communications Interface

Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)

Transfer Time

0 ms

Low Voltage Transfer to Battery Power (Setpoint)

160V (100% load), 140V (66% load), 120V (33% load)

High Voltage Transfer to Battery Power (Setpoint)

288V

Cold Start (Startup in Battery Mode During a Power Failure)

Cold-start operation supported

High Availability UPS Features

Automatic inverter bypass; Hot swappable batteries; Remote management; Surge/noise protection; Zero transfer time; Auto Probe Monitoring (requires WEBCARDLXE)

Green Energy-Saving Features

High efficiency economy mode operation; Individually controllable load banks

Grounding Details

Back panel grounding lug included

UPS Applications

High-End Desktop/Small Network

Product Certifications

CSA (Canada); UL 1778

Product Compliance

RoHS; FCC Part 15 Class A (USA)

Product Warranty Period (Worldwide)

2-year limited warranty

Connected Equipment Insurance (U.S., Canada & Puerto Rico)

$250,000 Ultimate Lifetime Insurance

TLWFLN72XX6009UC

2-Year Onsite Service Contract -2501-6000 VA UPS, Smart, SMX, SU systems

TLWFLN73XX6009UC

3-Year Onsite Service Contract -2501-6000 VA UPS, Smart, SMX, SU systems

TLWFLN75XX6009UC

5-Year Onsite Service Contract -2501-6000 VA UPS, Smart, SMX, SU systems

TL9SW3Y3000UC

3-Year Extended Warranty SU 2501-3000 VA UPS systems

TL9SW5Y3000UC

5-Year Extended Warranty SU 2501-3000 VA UPS systems

TLAS00NXXX6009UC

UPS Assembly on UPS Systems 0-6000 VA for select products, Smart, SMX, SU UPS

Part Number

Description

TLSU05NXXX6009UC

UPS Startup on UPS Systems 0-6000 VA for select products, Smart, SMX, SU UPS

Reviews

There are no reviews yet.

Be the first to review “Tripp Lite series SmartOnline 208/120V UPS With Step-Down Transformer – On-Line Double-Conversion, 3000VA 2700W, 4U, Network Card Option”

Your email address will not be published. Required fields are marked *

Compatible accessories