Tripp Lite SmartOnline 3kVA 2.7kW 120V Double-Conversion Sine Wave UPS – 7 Outlets, LCD, 2U Rack/Tower, TAA – SU3000RTXLCD2UTAA

$3,991.56

Brand: Tripp Lite
Part Number (MPN): SU3000RTXLCD2UTAA
UPC / GTIN: 786689875787
Datasheet: PDF

Tripp Lite series SmartOnline 3000VA 2700W 120V Double-Conversion Sine Wave UPS – 7 Outlets, Extended Run, Network Card Option, LCD, USB, DB9, 2U Rack/Tower, TAA

Status: On Backorder (Contact us for lead times)
Need project pricing? Add items to your cart to request a custom project quote.

Quick Specs

  • Offers network-grade protection against power failures and voltage fluctuations
  • Zero transfer time between on-line and battery modes for uninterrupted operation
  • Keeps equipment running during outages to allow time for file saves and safe shutdown
  • Optional WEBCARDLXE network interface enables 24/7 complete and remote control
  • Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases

Features

3kVA 2.7kW 120V Battery Backup Protects Equipment Against Damage, Downtime and Data Loss
This on-line double-conversion UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC. Constant on-line operation completely isolates sensitive equipment from every power problem on the AC line. The SmartOnline® SU3000RTXLCD2UTAA provides the highest level of power protection and battery backup for education, healthcare, military, government and other mission-critical IT applications where space is limited, but premium power reliability is essential.

Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in the case of a prolonged blackout. Zero transfer time between on-line and battery modes maintains continuous operation of connected equipment without interruption or rebooting.

Optional Network Management Card Allows 24/7 Remote Access
The WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options. Note: The SU3000RTXLCD2UTAA is not compatible with WEBCARDLX.

NEMA Outlets Protect Your Connected Components
One L5-30R and six 5-20R managed outlets provide connected equipment with pure sine wave AC output and allow you to manage power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Four 5-20R outlets are split evenly into two switchable load banks that let you reboot select components or shed non-critical loads in order to extend runtime for critical loads during an outage.

Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.

Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring
The two-line front-panel LCD features 10 selectable screens that allow quick access to a wide range of detailed UPS and site power information. LEDs show UPS status: a green light means utility power is on, an orange light means the UPS is in battery or bypass mode and a red light indicates an active alarm or fault. The control panel rotates to accommodate both rack-mount and tower configurations.

Advanced Communications Ports Allow for Automatic Saves and Shutdowns
RS-232 and USB ports connect to a device for a variety of communication options (cables are included). A dry-contact relay port can be programmed through the LCD to provide reliable communications to automation and industrial components. The RPO/ROO port permits emergency shutdown or remote restart of all connected equipment.

Automatically Turns Back On After Power Is Restored
Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even after a complete battery discharge. This can save you a costly site visit.

Versatile Installation Options
Hardware is included for mounting the UPS system in 2U of space in an EIA-standard 19-inch 4-post rack. You can also adapt it for 2-post rack mounting with the optional RK2PC (sold separately) or tower installation using the included support stands. The eight-foot power cord with NEMA 5-30P plug connects to any compatible AC outlet.

TAA-Compliant for GSA Schedule Purchases
The SU3000RTXLCD2UTAA is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

Package Includes

  • 3000VA 2700W 120V Double-Conversion UPS
  • USB cable
  • DB9 cable
  • Rack-mounting hardware
  • Tower support stands
  • Safety instructions
  • Quick Start Guide
Weight 92.0 lbs
Dimensions 39.5 × 24.1 × 9.1 in
UPC Code

786689875787

Cord Length

8.01

Max Input Amps

24

Rack Depth

26.8

Output (W)

2700

Output VA

3000

Joule Rating

190

Brand

UPS Type

On-Line

Input Phase

Single-Phase

Rated input current (Maximum Load)

24A

Nominal Input Voltage(s) Supported

100V AC; 110V AC; 120V AC

Nominal Input Voltage Description

120V factory default

UPS Input Connection Type

L5-30P

UPS Input Cord Length (ft.)

8

UPS Input Cord Length (m)

2.4

Input Plug Type

NEMA L5-30P

Input Cord Length (m)

2.44

Input Current

24A

Power Factor (Input)

0.99

Output Capacity (kVA)

3

Output Capacity (kW)

2.7

Power Factor

0.9

Crest Factor

3:1

Nominal Voltage Details

120V factory-default nominal voltage

Frequency Compatibility

50 / 60 Hz

Frequency Compatibility Details

Online Mode: Sync with line ±5% of nominal line frequency (outside this range: ±0.5% of auto-selected nominal frequency). Battery Mode: ±0.5% of auto-selected nominal frequency

Output Voltage Regulation (Line Mode)

+/- 1%

Output Voltage Regulation (Economy Line Mode)

+/- 1%

Output Voltage Regulation (Battery Mode)

+/- 2%

Load Management Receptacles

Two switchable two-outlet load banks

Output AC Waveform (AC Mode)

Pure Sine wave

Output (Watts)

2700

Output AC Waveform (Battery Mode)

Pure Sine wave

Nominal Output Voltage(s) Supported

100V; 110V; 115V; 120V; 127V

Output Receptacles

(6) 5-20R; (1) L5-30R

Individually Controllable Load Banks

Yes

Battery Type

Valve Regulated Lead Acid (VRLA)

Runtime Full Load (min.)

4.8 min. (2700W)

Runtime Half Load (min.)

13.9 min. (1350W)

Expandable Runtime

Yes

DC System Voltage (VDC)

72

Battery Recharge Rate (Included Batteries)

3 hours recharge to 90%

Battery Access

Battery access door

Internal UPS Replacement Battery Cartridge

744-A3122

Battery Replacement Description

Hot-swappable, user replaceable batteries

Capacity (Ah)

9

Voltage Regulation Description

Online, double-conversion power conditioning

Front Panel LCD Display

Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options

Switches

RPO / ROO

Alarm Cancel Operation

Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available

Audible Alarm

Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions

LED Indicators

4 status-indicating LEDs

EMI / RFI AC Noise Suppression

Yes

AC Suppression Joule Rating

190

AC Suppression Response Time

Instantaneous

Primary Form Factor

Rackmount

Rack Height

2U

Cooling Method

Fan

Installation Form Factors Supported with Optional Accessories

2 post rackmount ( RK2PC )

Minimum Required Rack Depth (cm)

68.07

Optional Mounting Accessory Notes

2 post rail kit available, part # RK2PC

Shipping Weight (kg)

35.30

UPS Housing Material

Metal

Unit Weight (kg)

28.60

Mounting Details

Includes 4 post rackmount installation accessories

Operating Temperature Range

32° to 104°F (0° to 40°C)

Storage Temperature Range

With battery: 32° to 104°F (0° to 40°C); without battery: -13° to 131°F (-25° to 55°C)

Relative Humidity

0-96% non-condensing

AC Mode Efficiency Rating (100% Load)

91.6

AC Economy Mode Efficiency Rating (100% Load)

97.2

Online Mode Heat Dissipation (BTU/Hr) @ Full Load

844

Battery Mode Heat Dissipation (BTU/Hr) @ Full Load

1462

Operating Elevation

0-10000 ft. (0-3000 m)

Audible Noise

47 dB at 1m

Network Management Cards

WEBCARDLXE

Network Monitoring Port Description

WEBCARDLXE Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications; not compatible with WEBCARDLX

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert

Communications Cable

USB and RS232 cable included

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

Network Management Card Description

Network management card optional

Communications Interface

(1) Contact closure; (1) RS-232; (1) Slot for SNMP/Web interface; (1) USB

Emergency Power Off (EPO)/Remote On-Off (ROO)

Yes

Transfer Time

0ms

Cold Start (Startup in Battery Mode During a Power Failure)

Cold-start operation supported

High Availability UPS Features

Expandable battery backup; Hot swappable batteries; On-Line/Double-Conversion; Remote management; Sine wave output; Surge/noise protection; Zero transfer time

Green Energy-Saving Features

High efficiency economy mode operation; Individually controllable load banks

UPS Applications

Mission Critical Applications

Product Certifications

UL 1778; cTUVus

Product Compliance

CE (Europe); FCC (USA); REACH; RoHS; Trade Agreements Act (TAA)

Product Warranty Period (Worldwide)

2-year limited warranty

Connected Equipment Insurance (U.S., Canada & Puerto Rico)

$250,000 Ultimate Lifetime Insurance

Extended Service Plans

ADVANCED DEPOT EXCHANGEService Part Number: TL9SW5Y-3000UCParts, electronics and UPS batteries coverageNext business day shippingTechnical support5-year onsite plan: TLWFLN75XX-6009UCOnsite parts and labor coverage for 5 yearsParts, electronics and UPS batteries coverage24x7 onsite labor coverage, next-day responseNext-day shippingTechnical support

Reviews

There are no reviews yet.

Be the first to review “Tripp Lite SmartOnline 3kVA 2.7kW 120V Double-Conversion Sine Wave UPS – 7 Outlets, LCD, 2U Rack/Tower, TAA – SU3000RTXLCD2UTAA”

Your email address will not be published. Required fields are marked *

Compatible accessories