Eaton 9PX 5.5kVA 4.9kW 120V/208V Double-Conversion UPS – L14-30P, 6x 5-20R, 1 L6-30R, 1 L14-30R, Hardwired Outlets, Network Card, 4U – 9PX6KSP

$7,971.60

Brand: Eaton
Part Number (MPN): 9PX6KSP
UPC / GTIN: 743172040336
Datasheet: PDF

Eaton 9PX 5500VA 4900W 120V/208V Online Double-Conversion UPS – L14-30P, 6x 5-20R, 1 L6-30R, 1 L14-30R, Hardwired Outlets, Cybersecure Network Card, Extended Run, 4U

Status: On Backorder (Contact us for lead times)
Need project pricing? Add items to your cart to request a custom project quote.

Quick Specs

  • Keeps equipment running during outages to allow time for file saves and safe shutdown
  • Included NETWORK-M2 Gigabit network card enables full remote access and control
  • Exclusive ABM technology with 3-stage charging increases internal battery life by 50%
  • Interactive LCD interface keeps you updated on critical load information in real time
  • Optional extended battery modules allow extended runtime to keep equipment powered

Features

5.5kVA/4.9kW Battery Backup for IT Installations and Edge Networks
This 9PX split-phase online double-conversion UPS system delivers both 120V and 208V output without the expense or extra weight of a bulky transformer or distribution module. The 9PX6KSP fits into just 4U of rack space and provides reliable battery backup and AC power protection against blackouts, brownouts, surges and line noise that can damage valuable IT equipment or destroy data. The 9PX6KSP is superlative power management for education, commercial, financial or healthcare networking components, including Cisco switches and servers.

Expandable Internal Battery Backup Keeps You Operational Through Power Outages
The field-replaceable, hot-swappable valve regulated lead acid (VRLA) battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Exclusive ABM technology increases battery life by 50 percent and closely monitors battery health to provide advanced notice when batteries need replacing. You can also connect up to four extended battery modules (9PXEBM240SP, sold separately) for hours of extended runtime.

Included Gigabit Network Interface Offers 24/7 Remote Access
The NETWORK-M2 Gigabit network card enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. UPS firmware can also be flashed remotely through the NETWORK-M2 without dropping the load, so you don’t have to plan for downtime. The card meets both UL 2900-1 and IEC 62443-4-2 standards for cybersecurity, which were developed to address the vulnerability of connected devices to known malware/exploits and to protect business from these risks. The optional Environmental Monitoring Probe Gen 2 (EMPDT1H1C2, sold separately) provides a variety of environmental monitoring capabilities, including temperature and humidity conditions.

NEMA Outlets Protect Your Connected Components
Six 5-20R, one L6-30R and one L14-30R managed outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. The 5-20R outlets are split evenly into two banks that let you shed non-critical loads to extend runtime for critical loads. The 9PX6KSP also supports hardwired output.

Rotating LCD Interface Keeps You Informed at a Glance
The intuitive front-panel LCD provides control settings and critical information to help diagnose any issues. The interface rotates to accommodate both rack-mount and tower configurations, and it tilts up to 45 degrees for more comfortable viewing.

Advanced Communications Ports Allow for Automatic Saves and Shutdowns
RS-232 and USB ports connect to a serial-enabled device for a variety of communication options (cables are included). A dry-contact relay port can be programmed through the LCD to provide reliable communications to automation and industrial components. The RPO/ROO connectors permit emergency shutdown or remote restart of all connected equipment.

Versatile Installation Options
You can mount the split-phase 9PX6KSP in just 4U of space in an EIA-standard 19-inch rack using the included 4-post rail kit. You can also adapt it for tower installation using the included support stands. The six-foot power cord with NEMA L14-30P plug connects to a compatible AC outlet. A cable gland and Phillips screwdriver are included for alternate hardwire input.

Package Includes

  • 5500VA 4900W 120V/208V 9PX Split-Phase Online Double-Conversion UPS with 8 Outlets
  • NETWORK-M2 Gigabit network card
  • (2) Internal battery modules
  • USB cable
  • RS-232 cable
  • Tower support stands
  • Cable gland for hardwire connection
  • Phillips-head screwdriver
  • Rack-mounting hardware
  • Owner’s manual
Weight 157.28 lbs
Dimensions 29.77 × 17.3 × 6.8 in
UPC Code

743172040336

Cord Length

5.91

Max Input Amps

24

Rack Depth

33

Output (W)

4900

Output VA

5500

Brand

UPS Type

On-Line

Input Phase

Single-Phase

Rated input current (Maximum Load)

24A

Nominal Input Voltage(s) Supported

120/208V (Split phase L1,L2,N,G); 120/240V (Split phase L1,L2,N,G)

UPS Input Connection Type

Hardwire; L14-30P

Input Circuit Breakers

Recommended 30A upstream

UPS Input Cord Length (ft.)

6

UPS Input Cord Length (m)

1.8

Input Plug Type

NEMA L14-30P

Output Capacity (kVA)

5.5

Output Capacity (kW)

4.9

Power Factor

0.82

Crest Factor

3:1

Nominal Voltage Details

100/200V, 110/220V, 115/230V, 120/208V, 120/240V, 127/220V

Frequency Compatibility

50 / 60 Hz

Output AC Waveform (Battery Mode)

Pure Sine wave

Nominal Output Voltage(s) Supported

120V; 208V; 240V; 100V; 200V; 110V; 220V; 115V; 230V; 127V

Output Receptacles

(6) 5-20R; (1) L6-30R; (1) L14-30R; Hardwire

Individually Controllable Load Banks

Yes

Battery Type

Valve Regulated Lead Acid (VRLA)

Runtime Full Load (min.)

6 min. (4900W)

Runtime Half Load (min.)

15 min. (2450W)

Expandable Runtime

Yes

Expandable Runtime Description

Add up to 4 extended battery modules (EBM). Part number 9PXEBM240SP

DC System Voltage (VDC)

240

Battery Access

Battery access door

Internal UPS Replacement Battery Cartridge

744-A2517

Battery Replacement Description

Hot-swappable, user replaceable batteries. UPS requires 2 Replacement Battery Cartridges.

Battery Management

ABM technology (3-stage charging extends battery service life by 50% and provides advance warning for battery replacement)

Front Panel LCD Display

LCD graphical display

Switches

RPO / ROO

Alarm Cancel Operation

Press ESC to silence the alarm

Audible Alarm

Audible alarm indicates utility failure, low-battery, overload, other UPS/Battery fault or remote shutdown conditions

EMI / RFI AC Noise Suppression

Yes

AC Suppression Response Time

0 ms

Primary Form Factor

Rackmount; Tower

Rack Height

4U

Cooling Method

Fan

Installation Form Factors Supported with Included Accessories

4 post 19 inch rackmount

Minimum Required Rack Depth (cm)

83.82

Unit Weight (kg)

71.35

Operating Temperature Range

32° to 104°F (0° to 40°C)

Relative Humidity

0-95% non-condensing

AC Mode Efficiency Rating (100% Load)

93

AC Economy Mode Efficiency Rating (100% Load)

97

Online Mode Heat Dissipation (BTU/Hr) @ Full Load

1275

Battery Mode Heat Dissipation (BTU/Hr) @ Full Load

1535

Network Management Cards

NETWORK-M2; INDGW-M2 ; RELAY-MS

Communications Interface

Pre-installed network card; RS-232; USB

High Availability UPS Features

On-Line/Double-Conversion; Pure sine wave output; Remote management; Surge/noise protection; Zero transfer time

UPS Applications

Mission Critical Applications

Product Certifications

cUL Listed; NOM (Mexico); EN 62040-2

Product Compliance

CE (Europe); ENERGY STAR Qualified; FCC Part 15 Class A (USA); RoHS

Product Warranty Period (U.S. & Canada)

3-year limited warranty

Extended Service Plans

ADVANCED DEPOT EXCHANGEService Part Number: 9SW5Y-6000UCExpedited parts coverage for 5 yearsParts, electronics and UPS batteries coverageNext business day shippingTechnical support5-YEAR ON-SITE PLAN (US ONLY)Service Part Number: WFLN75XX-6009UCOn-site parts and labor coverage for years 5Parts, electronics and UPS batteries coverage24x7 on-site labor coverage, next-day responseNext-day shippingTechnical support

Reviews

There are no reviews yet.

Be the first to review “Eaton 9PX 5.5kVA 4.9kW 120V/208V Double-Conversion UPS – L14-30P, 6x 5-20R, 1 L6-30R, 1 L14-30R, Hardwired Outlets, Network Card, 4U – 9PX6KSP”

Your email address will not be published. Required fields are marked *

Compatible accessories