Tripp Lite series 1.92kW 120V Single-Phase ATS/Local Metered PDU – 16 5-15/20R Outlets, Dual L5-20P/5-20P Inputs, 12 ft. Cords, 1U, TAA

$722.19

Brand: Tripp Lite
Part Number (MPN): PDUMH20ATS
UPC / GTIN: 037332261373
Datasheet: PDF

Tripp Lite series 1.92kW 120V Single-Phase ATS/Local Metered PDU – 16 5-15/20R Outlets, Dual L5-20P/5-20P Inputs, 12 ft. Cords, 1U, TAA

Status: On Backorder (Contact us for lead times)
Need project pricing? Add items to your cart to request a custom project quote.

Quick Specs

  • 16 NEMA 5-15/20R 120V outlets distribute AC power to connected equipment
  • Digital ammeter for on-site real-time load monitoring helps prevent power overloads
  • Dual 12 ft. cords with NEMA L5-20P inputs connect to separate power sources
  • Installs in 1U of space in EIA-standard 19 in. racks using included mounting brackets
  • Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases

Features

Single-Phase 20A ATS rack PDU (rPDU) Distributes and Monitors Network-Grade Power in Real Time
This local metered PDU provides real-time local reporting of the total load level via its built-in digital current metering. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMH20ATS features 16 NEMA 5-15/20R 120V outlets for connecting equipment. Dual 12-foot (3.7-meter) power cords with NEMA L5-20P inputs (two 5-20P adapters are included) connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources.

Switches from Primary to Secondary Power Source in Milliseconds
Automatic transfer switching (ATS) allows the PDU to switch to the secondary source within 2–7 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source.

Digital Load Meter Helps Prevent Potentially Expensive Overloads
A digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low.

Mounts into 1U of Rack Space or on a Wall
Use the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall or under a counter.

TAA-Compliant for GSA Schedule Purchases
The PDUMH20ATS is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

Package Includes

  • PDUMH20ATS 1.92kW Single-Phase ATS/Local Metered PDU
  • Detachable C19 to NEMA L5-20P secondary input cord, 12 ft. (3.7 m)
  • (2) L5-20R to 5-20P plug adapters
  • Cable Retention Kit
  • Rack-mounting hardware
  • Owner’s manual
Weight 20.7 lbs
Dimensions 20.1 × 23.3 × 5.4 in
UPC Code

037332261373

Cord Length

12.01

Max Input Amps

20

Rack Depth

19.5

Brand

PDU Type

Auto-Transfer Switch; Local Metered

Input Phase

Single-Phase

PDU Input Voltage

100; 120; 127

Maximum Input Amps Details

Agency de-rated to 16A maximum

Input Connection Type

Primary: Attached L5-20P, Secondary: C20 inlet with detachable C19-to-L5-20P cordset; L5-20-to-L5-20P adapters

PDU Plug Type

(2) NEMA 5-20P; (2) NEMA L5-20P

Input Cord Details

Set of two L5-20P cordsets with two 5-20P adapters enable connection to separate PRIMARY and SECONDARY power sources

Input Cord Length (m)

3.66

Output Capacity Details

2.03kW (127V), 1.92kW (120V), 1.6kW (100V) / 20A total capacity (Agency de-rated to 16A); 16A max per outlet

Frequency Compatibility

50 / 60 Hz

Output Receptacles

(16) 5-15/20R

Output Nominal Voltage

100V; 120V; 127V

Front Panel LCD Display

Digital display reports total PDU output current in amps

LED Indicators

16 front panel LEDs display power on / off status for each outlet, plus 2 additional LEDs to indicate input power status for primary and secondary inputs

Material of Construction

Metal

Rack Height

1U

Form Factors Supported

1U rackmount

Minimum Required Rack Depth (cm)

49.53

PDU Form Factor

Horizontal (1U)

Shipping Weight (kg)

9.39

Unit Dimensions (hwd / cm)

4.44 x 44.4 x 36.8

Unit Weight (kg)

5.53

Operating Temperature Range

32° to 104°F (0° to 40°C)

Storage Temperature Range

-22° to 122°F (-30° to 50°C)

Relative Humidity

5% to 95% non-condensing

Operating Elevation

0-10000 ft. (0-3000 m)

Grounding

Rear grounding lug

High Availability PDU Features

Auto-Transfer Switching

Product Certifications

CSA (Canada); NOM (Mexico); UL 60950-1

Product Compliance

RoHS; FCC Part 15 Class A (USA); Trade Agreements Act (TAA)

Product Warranty Period (Worldwide)

2-year limited warranty

WEXT1D

Extended Warranty and Technical Support for Select Products – Isolation Transformers, KVM, PDU, Inverters

WEXT2D

Extended Warranty and Technical Support for Select Products – Isolation Transformers, KVM Switches, PDUs, Power Inverters

WEXT3D

Extended Warranty and Technical Support for Select Products – Isolation Transformers, KVM Switches, PDUs, Power Inverters

Reviews

There are no reviews yet.

Be the first to review “Tripp Lite series 1.92kW 120V Single-Phase ATS/Local Metered PDU – 16 5-15/20R Outlets, Dual L5-20P/5-20P Inputs, 12 ft. Cords, 1U, TAA”

Your email address will not be published. Required fields are marked *