Tripp Lite series 5.8kW Single-Phase Monitored Automatic Transfer Switch PDU, 2 200-240V 30A L6-30P Inputs, 1 L6-30R Outlet, 1U

$1,575.16

Brand: Tripp Lite
Part Number (MPN): PDUMNH30HVAT
UPC / GTIN: 037332184917
Datasheet: PDF

Tripp Lite series 5.8kW Single-Phase Monitored Automatic Transfer Switch PDU, 2 200-240V 30A L6-30P Inputs, 1 L6-30R Outlet, 1U

Toronto Stock: 1 available
Manufacturer Warehouse: 105 available
*Items typically ship within 3-4 weeks if stock at factory
Need project pricing? Add items to your cart to request a custom project quote.

Quick Specs

  • Two single-phase L6-30P inputs with 10-ft. (3.05 m) cords
  • L6-30R outlet for connecting single device or 0U vertical PDU
  • Automatic transfer switching within 1-5 ms
  • Pre-installed WEBCARDLX with latest version of PADM20 for enhanced remote management
  • Digital LED display for real-time status monitoring

Overview

The PDUMNH30HVAT 5.8kW Single-Phase 200-240V Monitored Automatic Transfer Switch / ATS PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and features one L6-30R outlet—perfect for connecting a single device or a 0U 200-240V PDU with an L6-30P plug.Dual 10-ft. (3.05 m) input cords with L6-30P plugs connect to separate primary and secondary single-phase power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separate) provide a variety of environmental monitoring capabilities, including temperature and humidity conditions. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. DHCP/Manual configuration lets you assign network settings to the card automatically, reducing the need for manual configuration. Automated alerts help prevent accidental overloads, power loss and downtime.

Features

Primary and Secondary Inputs for Power Redundancy

  • Provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations
  • Dual 10-ft. (3.05 m) input cords with L6-30P plugs connect to separate primary and secondary single-phase power sources

Built-In L6-30R Outlet

  • Connects a single device or indirectly powers equipment through a 0U 200-240V rack PDU (rPDU) with L6-30P input (sold separately)

Automatic Transfer Switching

  • Dynamic solid-state (TRIAC) automatic transfer switching
  • Switches to secondary power source if primary source fails or becomes unstable
  • 1-5 ms transfer time ensures uninterrupted operation of connected equipment
  • Built-in processor monitors both sources and prevents switching if secondary source is unavailable or of lower quality than primary source

Multifunction Digital Display

  • Reports source A and source B input power status and other information, including power availability, line voltage, frequency, amps, kilowatts and power factor

Advanced Network Monitoring

  • Pre-installed WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities
  • PADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations
  • Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities
  • Real-time load/current data with billing-grade accuracy (+/- 1 percent)
  • Automated alerts help prevent accidental overloads, power loss and downtime

Broad Communications Compatibility

  • 10/100 Mbps auto-sensing allows optimal communication with 10/100 Base-T networks
  • Supports HTTP, HTTPS, PowerAlert®, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP and NTP

Mounts Horizontally in 1U of Rack Space

  • Compatible with EIA-standard 19 in. 4-post racks and rack enclosures
  • Optional PDU4PKIT rail kit adds rear rack-mounting support

Package Includes

  • PDUMNH30HVAT 5.8kW Single-Phase 200-240V ATS/Monitored PDU
  • Rack-mounting brackets
  • Owner’s manual
Weight 18.53 lbs
Dimensions 20.67 × 21.65 × 7.48 in
UPC Code

037332184917

Cord Length

10.01

Max Input Amps

24

Rack Depth

17.5

Brand

PDU Type

Monitored; Auto-Transfer Switch

Input Phase

Single-Phase

PDU Input Voltage

200; 208; 220; 230; 240

Maximum Input Amps Details

Agency de-rated to 24A continuous

PDU Plug Type

(2) NEMA L6-30P

Input Cord Details

Set of two inputs connect to separate PRIMARY and SECONDARY power sources

Input Cord Length (m)

3.05

Output Capacity Details

5.8kW (240V), 5.5kW (230V), 5.3kW (220V), 5.0kW (208V), 4.8kW (200V); 24A total capacity

Frequency Compatibility

50 / 60 Hz

Output Receptacle Details

Output receptacle is on a 61cm / 24 inch cordset

Output Receptacles

(1) L6-30R

Output Nominal Voltage

200-240V

Front Panel LCD Display

Digital display reports input current in amps (Source A, Source B), output kilowatts (total), input voltage (Source A, Source B), input frequency (Source A, Source B) and output power factor

Switches

ENTER and MODE switches toggle the digital display to display all reported information

LED Indicators

Front panel LEDs confirm amp (A) / kilowatt (kW) / voltage (V) / frequency (Hz) and power factor (PF) reporting information; Additional set of LEDs indicate Source A and Source B inputs for preferred, available and in-use status

Current Measurement Accuracy (Amps)

+/-1%

Voltage Measurement Accuracy (Volts)

+/-1%

Power Measurement Accuracy (Watts)

+/-1%

Material of Construction

Metal

Rack Height

1U

Form Factors Supported

1U rackmount

Minimum Required Rack Depth (cm)

44.45

PDU Form Factor

Horizontal (1U)

Shipping Dimensions (hwd / cm)

19.00 x 54.99 x 52.50

Shipping Weight (kg)

8.41

Unit Dimensions (hwd / cm)

4.4 x 43 x 35.6

Unit Weight (kg)

6.97

Operating Temperature Range

32° to 122°F (0° to 50°C)

Storage Temperature Range

-22° to 140°F (-30° to 60°C)

Relative Humidity

5% to 95% non-condensing

Operating Elevation

0-10000 ft. (0-3000 m)

PowerAlert Software

LX Platform Interface: PowerAlert Device Manager

Communications Cable

Micro-USB- to-USB A configuration/console Access cable

Network Monitoring Port

RJ45 Network port, Micro-USB Configuration port, USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules.

SNMP Compatibility

Pre-installed LX platform interface provides remote monitoring via Java-free HTML5 web interface, telnet, SSH and SNMP management systems

Network Compatibility

10 Mbps; 100 Mbps (Fast Ethernet)

High Availability PDU Features

Auto-Transfer Switching

Product Certifications

NOM (Mexico); UL 60950-1

Product Compliance

RoHS; FCC Part 15 Class A (USA)

Product Warranty Period (Worldwide)

2-year limited warranty

WEXT1H

Extended Warranty and Technical Support for Select Products – KVM, PDU, Inverters

WEXT2H

Extended Warranty and Technical Support for Select Products – KVM Switches, PDUs, Power Inverters

WEXT3H

Extended Warranty and Technical Support for Select Products – KVM Switches, PDUs, Power Inverters

Reviews

There are no reviews yet.

Be the first to review “Tripp Lite series 5.8kW Single-Phase Monitored Automatic Transfer Switch PDU, 2 200-240V 30A L6-30P Inputs, 1 L6-30R Outlet, 1U”