Eaton 7.7kW Single-Phase Switched PDU with LX Platform Interface, 230V Output, IEC 309 32A Blue, 10 ft. (3.05 m) Cord, 0U, TAA

$1,357.93

Brand: Tripp Lite
Part Number (MPN): PDUMV32HVNETLX
UPC / GTIN: 037332202352
Datasheet: PDF

Eaton 7.7kW Single-Phase Switched PDU with LX Platform Interface, 230V Output, IEC 309 32A Blue, 10 ft. (3.05 m) Cord, 0U, TAA

Manufacturer Warehouse: 22 available
*Items typically ship within 3-4 weeks if stock at factory
Need project pricing? Add items to your cart to request a custom project quote.

Quick Specs

  • 20 C13 and 4 C19 230V outlets distribute clean power to connected rack equipment
  • Compatible with Eaton Tripp Lite power cords to simplify deployment and enhance reliability
  • Pre-installed WEBCARDLX with latest version of PADM20 for IP-based Auto Probe feature
  • Remote power monitoring and control reduces on-site visits and maintenance costs
  • 10 ft. (3.1 m) power cord with IEC 309 32A Blue (2P+E) input connects to compatible AC source
  • Digital ammeter for on-site load monitoring helps prevent power overloads
  • Compatible with Eaton Tripp Lite power cords to simplify deployment and enhance reliability

Features

0U PDU Distributes, Monitors and Manages Network-Grade AC PowerRecommended for data centers, server rooms and network closets, this 0U vertical PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. You can more efficiently manage network power consumption and properly balance loads without having to visit the site. Reducing the number of on-site visits can help lower the cost of data center maintenance.24 Outlets Dispense Clean PowerDuring normal operation, 24 individually controllable outlets—20 C13 and four C19—distribute AC power to connected equipment. Each 230V outlet is accompanied by an LED that illuminates when the outlet is ramped up and ready to be used. The outlets are split into two load banks, each protected by a circuit breaker that trips if the bank’s connected load exceeds its maximum load rating. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged.Digital Load Meter Helps Prevent Potentially Expensive OverloadsA digital ammeter reports the load for each outlet bank separately and the total connected load. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. The firmware can be easily upgraded to ensure the PDU continues to perform at its best as connected equipment adds new features.Built-In LX Platform Network Management Card Allows Remote Access 24/7The built-in WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and PowerAlert Element Manager (PAEM) software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations. PADM20’s Auto Probe feature allows a PDU with switched loads to automatically reboot devices if a network communication failure is detected. This preserves uptime and minimizes the time and expense associated with on-site support. Easy to Install Vertically in an EIA-Standard 19 in. RackThe 0U rack PDU (rPDU) mounts vertically using the included toolless mounting buttons or the included brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. A 10-ft. (3.05 m) cord with IEC 309 32A Blue (2P+E) input plug connects the single-phase PDU to a compatible AC power source, generator or protected UPS system.TAA-Compliant for GSA Schedule PurchasesThe PDUMV32HVNETLX is compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases.2-Year WarrantyThe PDUMV32HVNETLX is backed by a 2-year warranty, ensuring reliability and performance.

Package Includes

  • PDUMV32HVNETLX 7.4kW Single-Phase Switched PDU
  • (24) Plug-lock insert sleeves
  • Rack-mounting hardware
  • Spare mounting buttons
  • PDUMVROTATEBRKT mounting bracket accessory
  • Owner’s manual
Weight 16.71 lbs
Dimensions 73.31 × 6.57 × 5.43 in
UPC Code

037332202352

Cord Length

10.01

Max Input Amps

32

Brand

PDU Type

Switched

Input Phase

Single-Phase

PDU Input Voltage

230

PDU Plug Type

IEC-60309 32A BLUE (2P+E)

Input Cord Length (m)

3.05

Output Capacity Details

7.7kW (240V), 7.4kW (230V), 7kW (220V), 6.7kW (208V), 6.4kW (200V) / 32A total capacity; 16A max per breakered outlet bank; 16A max per C19 outlet; 10A max per C13 outlet

Frequency Compatibility

50 / 60 Hz

Output Receptacle Details

Compatible with Eaton Tripp Lite Power Cords

Output Receptacles

(20) C13; (4) C19

Output Nominal Voltage

230V

Overload Protection

Two 20A circuit breakers protect 12 outlets each

Customized Load Management Receptacles

Each outlet is individually controllable via remote interface

Front Panel LCD Display

Digital display reports output amps in 3 separately metered loading segments (BANK 1: Outlets #1-12; BANK 2: Outlets #13-24; BANK 3: All outlets combined)

Switches

Pushbutton control scrolls visual load meter display from bank 1, bank 2 and band 1&2 combined. LX Platform Interface: Recessed reset switch for interface reboot and factory reset

LED Indicators

24 power availability LEDs confirm power off/on status for each built-in outlet. Network Link/Activity Status LED (Yellow), Network Speed LED (Green); LX Platform status LED (Green)

Rack Height

0U

Form Factors Supported

0U vertical rackmount. Includes mounting brackets. Supports toolless mounting in button-mount compatible racks

PDU Form Factor

Vertical (0U)

Shipping Dimensions (hwd / cm)

13.79 x 16.69 x 186.21

Shipping Weight (kg)

7.58

Unit Dimensions (hwd / cm)

177,6 x 5,6 x 10,8

Unit Weight (kg)

5.67

Operating Temperature Range

32° to 104°F (0° to 40°C)

Storage Temperature Range

-22° to 122°F (-30° to 50°C)

Relative Humidity

5% to 95% non-condensing

Operating Elevation

0-10000 ft. (0-3000 m)

PowerAlert Software

LX Platform Interface: PowerAlert Device Manager

Communications Cable

RJ45-to-DB9 configuration/console Access cable

Network Monitoring Port

RJ45 Network port, RJ45 Serial Config/Console Access port; USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules.

SNMP Compatibility

Pre-installed LX platform interface provides remote monitoring via Java-free HTML5 web interface, telnet, SSH and SNMP management systems

Network Compatibility

10 Mbps; 100 Mbps (Fast Ethernet)

High Availability PDU Features

Auto Probe Monitoring and Reboot (included); Auto Load Shedding

Product Certifications

EN 60950-1

Product Compliance

RoHS; CE (Europe); Trade Agreements Act (TAA)

Product Warranty Period (Worldwide)

2-year limited warranty

WEXT1H

Extended Warranty and Technical Support for Select Products – KVM, PDU, Inverters

WEXT2H

Extended Warranty and Technical Support for Select Products – KVM Switches, PDUs, Power Inverters

WEXT3H

Extended Warranty and Technical Support for Select Products – KVM Switches, PDUs, Power Inverters

Reviews

There are no reviews yet.

Be the first to review “Eaton 7.7kW Single-Phase Switched PDU with LX Platform Interface, 230V Output, IEC 309 32A Blue, 10 ft. (3.05 m) Cord, 0U, TAA”

Your email address will not be published. Required fields are marked *