Tripp Lite SmartPro 750VA 750W 120V Line-Interactive Sine Wave UPS – 8 Outlets, Network Card Included, LCD, 2U Rack/Tower – SMART750RMXL2UN

$1,644.26

Brand: Tripp Lite
Part Number (MPN): SMART750RMXL2UN
UPC / GTIN: 037332256409
Datasheet: PDF

Tripp Lite series SmartPro 750VA 750W 120V Line-Interactive Sine Wave UPS – 8 Outlets, Extended Run, Network Card Included, LCD, USB, DB9, 2U Rack/Tower

Manufacturer Warehouse: 26 available
*Items typically ship within 3-4 weeks if stock at factory
Need project pricing? Add items to your cart to request a custom project quote.

Quick Specs

  • Protects equipment against blackouts, brownouts, transient surges and line noise
  • Keeps equipment running during outages to allow time for file saves and safe shutdown
  • Unity power factor ensures maximum power possible at each power rating
  • Included WEBCARDLXE network interface allows 24/7 remote access and control
  • 2-line front-panel LCD with 10 selectable screens reports detailed UPS and site power info

Features

750VA/750W/120V Battery Backup for Distributed IT, Telecom or Enterprise Deployments
The SMART750RMXL2UN provides reliable battery backup and AC power protection for connected devices against blackouts, brownouts, surges and line noise. Unity power factor ensures the most watts possible at each power rating, so you can connect more equipment. Pure sine wave power and unity power factor, even when on battery, means this SmartPro® UPS can be used with sensitive IT equipment, including servers, VoIP phones, data storage and PoE switches. Even if the battery is depleted, the UPS will automatically restart when the power comes back on after an extended outage.

Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Switchover from line to battery power happens within milliseconds to maintain continuous operation of connected equipment without interruption or rebooting. Extra runtime is available by connecting up to four optional extended battery modules (BP48VRM2U, sold separately).

Pre-Installed LX Platform Network Management Card Allows Remote Access 24/7
The WEBCARDLXE network interface enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.

NEMA 5-15R Outlets Protect Your Connected Components
Eight 5-15R outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Four outlets are grouped into two programmable load banks that let you shed non-critical loads to extend runtime for critical loads. Front and rear cooling fans help protect equipment from overheating.

Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring 
The two-line front-panel LCD monitoring screen features ten selectable screens that allow quick access to a wide range of detailed UPS and site power information. LEDs show UPS status: a green light means utility power is on, an orange light means the UPS is in battery mode and a red light indicates an active alarm or fault. The control panel rotates to accommodate both rack-mount and tower configurations.

Automatic Voltage Regulation (AVR) Corrects Low- and High-Voltage Conditions
AVR protects your equipment from incremental hardware damage, data loss and performance problems caused by brownouts. The SMART750RMXL2UN maintains regulated 120V nominal output during brownouts and overvoltages from 80V to 151V while keeping the battery fully charged and ready to take over in case of power failure.

Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
This UPS filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.

Advanced Communications Ports Allow for Automatic Saves and Shutdowns
RS-232 and USB ports allow local control of the UPS and its advanced features when remote access is unavailable (cables are included). A dry-contact relay port can be programmed through the LCD to provide reliable communications to automation and industrial components. The RPO/ROO (Remote Power On/Remote On Off) port permits emergency shutdown or remote restart of the UPS and all connected equipment.

Versatile Deployment Options
You can mount the SMART750RMXL2UN in just 2U of space in an EIA-standard 19-inch rack using the included hardware. You can also adapt it for tower installation using the included support stands. The six-foot (1.8-meter) power cord with NEMA 5-15P plug connects to a compatible AC outlet.

Package Includes

  • 750VA 750W 120V Line-Interactive UPS
  • WEBCARDLXE network management card
  • USB cable
  • DB9 cable
  • Rack-mounting hardware
  • Tower support stands
  • Quick Start Guide with safety instructions
Weight 45.5 lbs
Dimensions 23.3 × 18.6 × 8.7 in
UPC Code

037332256409

Cord Length

5.91

Max Input Amps

8

Rack Depth

16.2

Output (W)

750

Output VA

750

Joule Rating

380

Brand

UPS Type

Line-Interactive

Input Phase

Single-Phase

Rated input current (Maximum Load)

7.5A

Nominal Input Voltage(s) Supported

120V AC

Nominal Input Voltage Description

80V-151V; adjustable to 70-153V

UPS Input Connection Type

5-15P

UPS Input Cord Length (ft.)

6

UPS Input Cord Length (m)

1.8

Output Capacity (kVA)

0.75

Output Capacity (kW)

0.75

Power Factor

1

Nominal Voltage Details

120v nominal output in battery mode

Frequency Compatibility

50 / 60 Hz

Output Voltage Regulation (Line Mode)

120V (-13%, +15%)

Output Voltage Regulation (Battery Mode)

-10%, +6%

Load Management Receptacles

Two switchable two-outlet 5-15R load banks

Output AC Waveform (AC Mode)

Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

Nominal Output Voltage(s) Supported

110V; 115V; 120V

Output Receptacles

(8) 5-15R

Individually Controllable Load Banks

Yes

Battery Type

Valve Regulated Lead Acid (VRLA)

Runtime Full Load (min.)

8.5 min. (750W)

Runtime Half Load (min.)

20.7 min. (375W)

Expandable Runtime

Yes

Expandable Battery Runtime

Extended runtime supported via optional external battery packs

External Battery Pack Compatibility

BP48VRM2U (limit 4)

DC System Voltage (VDC)

48

Battery Recharge Rate (Included Batteries)

Less than 4.5 hours from 10% to 90% (typical, full load discharge)

Battery Access

Front panel battery access door

Internal UPS Replacement Battery Cartridge

Pre-February 2024: RBC24V-LCD Post-March 2024: EBP-1612

Battery Replacement Description

48V DC Hot-swappable, user replaceable batteries

Voltage Regulation Description

Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 150V (Normal mode) adjustable to 70-153V (Extended mode)

Overvoltage Correction

Reduces incoming voltage between 132-151V by 13% (Normal Mode); 138-152V (Extended mode)

Undervoltage Correction

Boost incoming voltages between 81-102V by 15% (Normal Mode); 71-92V by 15% (Extended Mode)

Front Panel LCD Display

Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)

Switches

5 pushbutton switches control OFF / ON power status, ENTER, UP, and DOWN selection and ESC control functions. LX Platform Interface: Recessed reset switch for interface reboot and factory reset

Alarm Cancel Operation

Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available

Audible Alarm

Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions

LED Indicators

UPS: 3 status-indicating LEDs (normal, battery mode, alarm/fault); LED colors (green = ON, orange = On battery, flashing orange = below warning level, red = alarm/fault). LX Platform Interface Status: Network Link/Activity (Green): Flashes for network activity. Network Speed (Yellow): 10 Mbps (Flashing), 100 Mbps (On steady). Normal Operation (Solid Green); Software Update (Alternating Green/Orange ~1/sec); Factory Reset (Alternating Green/Orange ~2/sec).

EMI / RFI AC Noise Suppression

Yes

AC Suppression Joule Rating

380

Primary Form Factor

Rackmount

Rack Height

2U

Cooling Method

Fan

Installation Form Factors Supported with Optional Accessories

2 post rackmount ( 103007018-5591 ); 4 post rackmount short-depth ( 4POSTRAILKITWM )

Minimum Required Rack Depth (cm)

41.15

Minimum Required Rack Depth with External Battery Pack (in.)

20

Minimum Required Rack Depth without External Battery Pack (in.)

21

Optional Mounting Accessory Notes

Optional 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm)

Primary UPS Depth (mm)

334

Primary UPS Height (mm)

88

Primary UPS Width (mm)

441

Shipping Weight (kg)

20.64

UPS Housing Material

Steel

UPS Power Module Weight (kg)

16.06

Mounting Details

Included 4-post mounting brackets that enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm). The tower stands are included to support tower orientation.

Operating Temperature Range

32° to 104°F (0° to 40°C)

Storage Temperature Range

5° to 122°F (-15° to 50°C)

Relative Humidity

0-95% non-condensing

AC Mode BTU / Hr. (Full Load)

70

AC Mode Efficiency Rating (100% Load)

95%

Battery Mode Heat Dissipation (BTU/Hr) @ Full Load

465

Operating Elevation

0-10000 ft. (0-3000 m)

Audible Noise

45 dBA maximum, front side 1m

Storage Elevation (m)

0-10,000

Network Management Cards

WEBCARDLXE

Network Monitoring Port Description

Pre-installed WEBCARDLXE supports detailed monitoring and management of UPS and site power conditions. Not compatible with WEBCARDLX

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert Office software at https://tripplite.eaton.com/products/power-alert

Communications Cable

Micro-USB, USB and DB9 cabling included

Network Monitoring Port

RJ45 Network port, Micro-USB Configuration/Console port, USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules.

SNMP Compatibility

SNMP V1, V2c, V3

Network UPS Tools (NUT) Compatibility

NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite

Network Compatibility

10 Mbps; 100 Mbps (Fast Ethernet)

Network Management Card Description

Network management card included

Communications Interface

DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface; USB (HID enabled)

Transfer Time

4 milliseconds (AC to battery mode), 2 milliseconds (Battery to AC mode)

Low Voltage Transfer to Battery Power (Setpoint)

83

High Voltage Transfer to Battery Power (Setpoint)

151

Cold Start (Startup in Battery Mode During a Power Failure)

Cold-start operation supported

High Availability UPS Features

Auto Probe Monitoring and Reboot (included); Automatic Voltage Regulation (AVR); Expandable battery backup; Hot swappable batteries; Remote management; Sine wave output; Surge/noise protection

Grounding Details

Rear panel grounding lug

UPS Applications

High-End Desktop/Small Network; Audio/Video; Home Network; Smart Home

Product Certifications

CAN/CSA-C22.2 No. 107.3 (Canada); CSA (Canada); ICES (Canada); NOM (Mexico); UL 1778

Product Compliance

CE (Europe); FCC Part 15 Class A (USA); RoHS

Product Warranty Period (Worldwide)

2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty.

Connected Equipment Insurance (U.S., Canada & Puerto Rico)

$250,000 Ultimate Lifetime Insurance

TLWFLN72XX2509UC

2-Year Onsite Service Contract -0-2500 VA UPS, Smart, SMX, SU systems

TLWFLN73XX2509UC

3-Year Onsite Service Contract -0-2500 VA UPS, Smart, SMX, SU systems

TLWFLN75XX2509UC

5-Year Onsite Service Contract -0-2500 VA UPS, Smart, SMX, SU systems

TL5SW5Y0950UC

5-Year Extended Warranty Smart & SMX 0-950 VA UPS systems

TL5SW5Y1400UC

5-Year Extended Warranty Smart & SMX 951-1400 VA UPS systems

TLAS00NXXX6009UC

UPS Assembly on UPS Systems 0-6000 VA for select products, Smart, SMX, SU UPS

Part Number

Description

TLSU05NXXX6009UC

UPS Startup on UPS Systems 0-6000 VA for select products, Smart, SMX, SU UPS

Reviews

There are no reviews yet.

Be the first to review “Tripp Lite SmartPro 750VA 750W 120V Line-Interactive Sine Wave UPS – 8 Outlets, Network Card Included, LCD, 2U Rack/Tower – SMART750RMXL2UN”

Your email address will not be published. Required fields are marked *

Compatible accessories