Tripp Lite series 5.5kW Single-Phase Local Metered PDU – 16 C13 & 2 C19 Outlets (208/230V), L6-30P Input, 1.8 m Cord, 2U, TAA

$574.71

Brand: Tripp Lite
Part Number (MPN): PDUMH30HV6
UPC / GTIN: 037332256584
Datasheet: PDF

Tripp Lite series 5.5kW Single-Phase Local Metered PDU – 16 C13 & 2 C19 Outlets (208/230V), L6-30P Input, 1.8 m Cord, 2U, TAA

Status: On Backorder (Contact us for lead times)
Need project pricing? Add items to your cart to request a custom project quote.

Quick Specs

  • 16 C13 and 2 C19 208/230V outlets distribute AC power to connected equipment; Compatible with Eaton Tripp Lite power cords.
  • Digital ammeter for on-site load monitoring helps prevent power overloads
  • 1.8 m cord with NEMA L6-30P single-phase input connects to AC power source
  • Local Metered PDU installs in 2U of rack space using the included mounting brackets
  • Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases

Features

Single-Phase PDU Distributes and Monitors Network-Grade PowerThis local metered rack PDU (rPDU) provides real-time monitoring of load levels via its built-in digital current metering. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMH30HV6 features 16 C13 and two C19 208/230V outlets in two separately breakered load banks, which distribute AC power to rack equipment. The banks can be individually monitored to ensure proper load balance and make any necessary upgrades before the PDU becomes overloaded. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged.Digital Load Meter Helps Prevent Potentially Expensive OverloadsA digital ammeter reports the load for each outlet bank separately, so you can balance loads across both built-in 20A breakers. Add the two load-bank current values together to determine total input current. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels can keep your TCO (total cost of ownership) low.2U PDU Easy to Install in an EIA-Standard 19 in. RackThe reversible all-metal housing installs in 2U of rack space using the included hardware and user-supplied screws. The 1.8-meter (six-foot) cord with NEMA L6-30P input plug connects the single-phase PDU to a protected UPS system, generator or mains input source for reliable multi-outlet power distribution.TAA-Compliant for GSA Schedule PurchasesThe PDUMH30HV6 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

Package Includes

  • PDUMH30HV6 5.5kW Single-Phase Local Metered PDU
  • (18) Plug-lock insert sleeves
  • Rack-mounting hardware
  • Owner’s manual
Weight 15.8 lbs
Dimensions 19.8 × 16.7 × 7.8 in
UPC Code

037332256584

Cord Length

6

Max Input Amps

24

Rack Depth

16

Brand

PDU Type

Local Metered

Input Phase

Single-Phase

PDU Input Voltage

208; 230

Maximum Input Amps Details

Agency de-rated to 24A continuous

PDU Plug Type

NEMA L6-30P

Input Cord Length (m)

1.83

Output Capacity Details

5.5kW (230V), 5kW (208V) total capacity / 30A max (Agency de-rated to 24A), 20A max per breakered outlet bank; 16A max per C19 outlet; 12A max per C13 outlet

Frequency Compatibility

50 / 60 Hz

Output Receptacle Details

Compatible with Eaton Tripp Lite Power Cords

Output Receptacles

(16) C13; (2) C19

Output Nominal Voltage

208/230V

Overload Protection

Two 20A breakers protect 9 outlets each

Front Panel LCD Display

Set of 2 digital meters continuously report output current for breakered load banks 1 & 2 (Bank 1: upper row of 9 outlets / Bank 2: lower row of 9 outlets)

Material of Construction

Metal

Rack Height

2U

Form Factors Supported

2U rackmount; mounting accessories included

Minimum Required Rack Depth (cm)

40.64

PDU Form Factor

Horizontal (2U)

Shipping Weight (kg)

7.17

Unit Dimensions (hwd / cm)

8.8 x 44.4 x 31.8

Unit Weight (kg)

6.21

Operating Temperature Range

32° to 104°F (0° to 40°C)

Storage Temperature Range

-22° to 122°F (-30° to 50°C)

Relative Humidity

5% to 95% non-condensing

Operating Elevation

0-10000 ft. (0-3000 m)

Grounding

Grounding lug

Product Certifications

NOM (Mexico); UL 62368-1

Product Compliance

RoHS; FCC Part 15 Class A (USA); UKCA; Trade Agreements Act (TAA)

Product Warranty Period (Worldwide)

2-year limited warranty

Part Number

Description

WEXT1D

Extended Warranty and Technical Support for Select Products – Isolation Transformers, KVM, PDU, Inverters

WEXT2D

Extended Warranty and Technical Support for Select Products – Isolation Transformers, KVM Switches, PDUs, Power Inverters

WEXT3D

Extended Warranty and Technical Support for Select Products – Isolation Transformers, KVM Switches, PDUs, Power Inverters

Reviews

There are no reviews yet.

Be the first to review “Tripp Lite series 5.5kW Single-Phase Local Metered PDU – 16 C13 & 2 C19 Outlets (208/230V), L6-30P Input, 1.8 m Cord, 2U, TAA”

Your email address will not be published. Required fields are marked *