Tripp Lite series 5.8kW 208/240V Single-Phase ATS/Monitored PDU – 16 C13, 2 C19 & 1 L6-30R Outlets, Dual L6-30P Inputs, 10 ft. Cords, 2U, TAA

$1,621.55

Brand: Tripp Lite
Part Number (MPN): PDUMNH30HVAT2
UPC / GTIN: 037332261434
Datasheet: PDF

Tripp Lite series 5.8kW 208/240V Single-Phase ATS/Monitored PDU – 16 C13, 2 C19 & 1 L6-30R Outlets, Dual L6-30P Inputs, 10 ft. Cords, 2U, TAA

Manufacturer Warehouse: 24 available
*Items typically ship within 3-4 weeks if stock at factory
Need project pricing? Add items to your cart to request a custom project quote.

Quick Specs

  • Built-in HTML5-based LX Platform interface allows you 24/7 remote access
  • Enables redundant A/B power option for single-corded network devices
  • Digital meter for real-time voltage, amp and load monitoring helps prevent overloads
  • Compatible with Eaton Tripp Lite power cords to simplify deployment and enhance reliability
  • Dual 10 ft. cords with NEMA L6-30P inputs connect to separate power sources
  • Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases

Features

Single-Phase 30A 208V/240V ATS rack PDU (rPDU) Distributes and Monitors Network-Grade Power in Real Time
This monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via its built-in network interface. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMNH30HVAT2 features 16 C13, 2 C19, and NEMA L6-30P outlets for connecting equipment. Dual 10-foot (3.1-meter) power cords with NEMA L6-30P inputs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources.

Switches from Primary to Secondary Power Source in Milliseconds
Dynamic solid-state automatic transfer switching (ATS) allows the PDU to switch to the secondary source within 1-5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source.

Built-In LX Platform Network Management Card Allows Remote Access 24/7
The Java-free HTML5-based WEBCARDLX network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. The latest version of PowerAlert Device Manager (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations.

Digital Load Meter Helps Prevent Potentially Expensive Overloads
A digital ammeter reports the total load for all connected equipment in amps and kilowatts. Monitoring capacity helps ensure load levels remain well below maximum capacity levels with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low. Current monitoring provides 1% billing grade accuracy.

Mounts into 2U of Rack Space or on a Wall
Use the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall or under a counter.

TAA-Compliant for GSA Schedule Purchases
The PDUMNH30HVAT2 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

Package Includes

  • PDUMNH30HVAT2 5.8kW Single-Phase ATS/Monitored PDU
  • Configuration cable, USB-A to USB Micro-B
  • Rack-mounting hardware
  • Installable plug-retention sleeves
  • Cable ties
  • Owner’s manuals
Weight 17.3 lbs
Dimensions 20.2 × 16.7 × 7.8 in
UPC Code

037332261434

Cord Length

10.01

Max Input Amps

30

Rack Depth

16

Brand

PDU Type

Auto-Transfer Switch; Local Metered; Monitored

Input Phase

Single-Phase

PDU Input Voltage

200; 208; 240

Maximum Input Amps Details

Agency de-rated to 24A continuous

PDU Plug Type

(2) NEMA L6-30P

Input Cord Details

Set of two inputs connect to separate PRIMARY and SECONDARY power sources

Input Cord Length (m)

3.05

Output Capacity (kW)

5.8

Output Capacity Details

5kW (208/240V), 4.8kW (200V) total capacity / 30A max (Agency de-rated to 24A), 24A max per L6-30R outlet; 20A max per breakered outlet bank; 16A max per C19 outlet; 12A max per C13 outlet

Frequency Compatibility

50 / 60 Hz

Output Receptacle Details

Compatible with Eaton Tripp Lite Power Cords

Output Receptacles

(16) C13; (2) C19; (1) L6-30R

Output Nominal Voltage

200V; 208V; 240V

Overload Protection

Includes two 20A output circuit breakers; Breaker 1 controls the upper row of 9 outlets (8 C13, 1 C19); Breaker 2 controls the lower row of outlets (8 C13, 1 C19); L6-30R outlet is unbreakered

Front Panel LCD Display

Digital display reports output amps in 4 separately metered loading segments (BANK 1: Outlets #1-9; BANK 2: Outlets #10-18; BANK 3: Outlet #19), whole-PDU output kW load level and input voltage on primary and secondary input lines, and IP address. Temp and Humidity will display if optional Envirosense2 modules are attached.

Switches

ENTER and MODE switches toggle the digital display to show output amps (Banks 1-4), total kW output and input voltage (primary, secondary), and IP address.

LED Indicators

Front panel LEDs confirms amp / kilowatt / voltage reporting information along with active primary and secondary input source status

Material of Construction

Metal

Rack Height

2U

Form Factors Supported

2U rackmount

Minimum Required Rack Depth (cm)

40.64

PDU Form Factor

Horizontal (2U)

Shipping Weight (kg)

7.85

Unit Dimensions (hwd / cm)

8.8 x 44.4 x 31.7

Unit Weight (kg)

6.21

Operating Temperature Range

32° to 104°F (0° to 40°C)

Storage Temperature Range

-22° to 122°F (-30° to 50°C)

Relative Humidity

5% to 95% non-condensing

Operating Elevation

0-10000 ft. (0-3000 m)

PowerAlert Software

LX Platform Interface: PowerAlert Device Manager

Communications Cable

Micro-USB- to-USB A configuration/console Access cable

Network Monitoring Port

RJ45 Network port, Micro-USB Configuration port, USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules.

SNMP Compatibility

Yes

Network Compatibility

10 Mbps; 100 Mbps (Fast Ethernet)

Network Speed Details

10 / 100

Communications Interface

(1) DB9 Serial; (1) Micro-USB; (1) Pre-installed network card; (1) RJ45 Network; (1) USB-A

High Availability PDU Features

Auto-Transfer Switching

Product Certifications

NOM (Mexico); UL 60950-1

Product Compliance

RoHS; FCC Part 15 Class A (USA); Trade Agreements Act (TAA)

Product Warranty Period (Worldwide)

2-year limited warranty

WEXT1K

Extended Warranty and Technical Support for Select Products – Cooling, KVM, PDUs, Power Inverters

WEXT2K

Extended Warranty and Technical Support for Select Products – KVM, PDUs, Power Inverters

WEXT3K

Extended Warranty and Technical Support for Select Products – KVM, PDUs, Inverters

Reviews

There are no reviews yet.

Be the first to review “Tripp Lite series 5.8kW 208/240V Single-Phase ATS/Monitored PDU – 16 C13, 2 C19 & 1 L6-30R Outlets, Dual L6-30P Inputs, 10 ft. Cords, 2U, TAA”